ÐͺţºCP/CN/CTϵÁÐUFMÎнÖÁ÷Á¿¼ÆÊÊÓÃÓÚË®£¬Ë®/ÒÒ¶þ´¼ÀäÈ´¼Á»òµÍÕ³¶ÈÁ÷Ì壬רΪÀäÈ´¼Á»òË®Á÷Á¿²âÁ¿Éè¼Æ£¬Ò»Ð©´ó³ß´ç¿Ú¾¶»¹¿É´øÓÐζȱäËÍÆ÷£¬¾ßÓвâÁ¿Î¶ȺÍ/»òÁ÷Á¿µÄģʽ¡£UFMÎнÖÁ÷Á¿¼Æ¾ßÓÐLEDÊý×ÖÏÔʾ¡£UFMÎнÖÁ÷Á¿¼Æ½á¹¹¼òÒס¢ÖÊÁ¿¿É¿¿¡¢Î޻²¿¼þ£¬¹ÊÕϺÍÄ¥ËðÉÙ¡£UFMÎнÖÁ÷Á¿¼Æ¾ßÓÐÁ÷Á¿±äËÍÆ÷Êä³ö4-20mA¡¢Î¶ȱäËÍÆ÷Êä³ö4-20mA¡¢¹Ì̬¼ÌµçÆ÷¿ÉÓÃ×÷±¨¾¯»òÂö³åÊä³ö¡£UFM vortex shedding flowmeters are designed for coolant or water flow. They come in ? to 4 inch pipe sizes with a temperature transmitter option available in ? to 4 inch sizes. Suitable for low viscosity corrosive fluids with our 316 Stainless Steel body and Kalrez seal options. Cost a lot less than mag meters and are okay with high particulate.
UFMÎнÖÁ÷Á¿¼Æ¹ã·ºÓ¦ÓÃÓÚ¸ÐÓ¦ÈÈ´¦Àí¡¢¸ÐӦ¯¡¢ÂÖ̥ģ¾ß¡¢ÈÈ×躸»ú¡¢ÃÜ·âË®µÈ¡£
²úÆ·Ãû³Æ£ºUNIVERSAL CoolPointÎнÖÁ÷Á¿¼Æ²úÆ·ÐÔÄܲÎÊý
½á¹¹¼òÒס¢ÖÊÁ¿¿É¿¿¡¢Î޻²¿¼þ£¬¹ÊÕϺÍÄ¥ËðÉÙ
LED3λÏÔʾ£¬±¨¾¯Ê±ÉÁ˸£¬Á÷Á¿¼°Î¶ȱäËÍÆ÷
ζȷ¶Î§£º85°C£¨***´ó¿É´ï99°C£©
¾«¶È£º+/-2£¥£¨Á÷Á¿£©/+/-1%£¨Î¶ȣ©ÂúÁ¿³Ì
Öظ´ÐÔ£º+/-0.25£¥£¨Êµ¼ÊÁ÷Á¿/ζȣ©Á÷Á¿·¶Î§£º2LPM¡«2271LPM
Á¿³Ì±È£º¸÷ÖÖζÈÏ£¬10:1£»±ê׼ζÈÏÂ(¿ÉÑ¡)£¬20:1
ÏìӦʱ¼ä£º3S£¨Á÷Á¿£©£û1.8S£¨Î¶ȣ©£ýµ½´ï63£¥
¹Ü¾¶·¶Î§£º1/4”NPTF¡«4”150#·¨À¼Á¬½Ó¿ÇÌåµÈ¼¶£ºIP65£¬ÀàÐÍ1,3,4,12ºÍ13
ÈÏÖ¤£ºCSA\CE\ATEX
²úÆ·ÔÀíUFMÎнÖÁ÷Á¿¼ÆÁ÷Á¿²âÁ¿²ÉÓÃÎнÖÔÀí£ºÁ÷Ìå¾¹ýÒ»¸öÎïÌå»òÕÏ°Îï²úÉúÕñ¶¯£¨äöÎУ©¡£UFMÎнÖÁ÷Á¿¼Æ²ÉÓÃÒ»¸ö·ÇÁ÷ÏßÐεı¾Ìå×÷ΪÕÏ°ÎÔö¼ÓÁ÷Á¿¾ÍÔö¼ÓÕñ¶¯µÄƵÂÊ£¬Ò»¸ö´«¸ÐÆ÷¼ì²âÕñ¶¯£¬±äËÍÆ÷²úÉúÒ»¸öÁ÷Á¿Ðźţ»Î¶ȲâÁ¿²ÉÓùÌ̬´«¸ÐÆ÷¼¼Êõ¡£
CPϵÁÐÁ÷Á¿·¶Î§: .4-600GPM (1.5µ½2250LPM)
***´óҺѹ: 300PSI (20Bar)Ò»°ã˵Ã÷£º CPϵÁÐÁ÷Á¿¼ÆÓÃÓÚË®¡¢Ë®£¯¶þÔª´¼ÀäÈ´¼Á»òµÍÕ³¶ÈÒºÌå¡£
Ëü¾ßÓÐÒÔÏÂһЩÌØÐÔ£º
4-20 mA Á÷Á¿´«¸ÐÆ÷
ijЩ¿Ú¾¶Á÷Á¿¼Æ¿ÉÒÔÌṩ 316²»Ðâ¸Ö²ÄÖÊ
ijЩ¿Ú¾¶Á÷Á¿¼Æ¿ÉÒÔÑ¡ÓÃζȴ«¸ÐÆ÷
Âö³åÊä³ö
LED Êý×ÖÏÔʾÆ÷
Óû§¿ÉÅäÖñ¨¾¯É趨µã
ûÓлá¶ÂÈû»òÄ¥ËðµÄÔ˶¯²¿¼þ
ÓÐ CSA ºÍ CE ÈÏÖ¤µçÆø¹æ¸ñ:
Êä³ö 4-20 mA
±¨¾¯»òÂö³åÊä³ö SPST ¹Ì̬¼ÌµçÆ÷ (NC »ò NO£¬¿ÉÑ¡Ôñ)
1/4" ºÍ 1/2" ≤185°F (85°C) -250 mA,
>185°F (85°C) -100 mA
3/4" µ½ 4" ≤185°F (85°C) -125 mA,
>185°F (85°C) -50 mA
ÊäÈ빦ÂÊ 10 - 30 VDC @ 80 mA
µçÆøÁ¬½Ó
Õë½Å½ÓÍ·(±ê×¼ÅäÖÃ)
½Óµç³éÍ·(¿ÉÑ¡)
´øÓнÓÏßÌõµÄ½ÓÏߺÐ(¿ÉÑ¡)²ÄÁϹæ¸ñ:
Á÷Á¿¼ÆÖ÷Ìå²ÄÁÏΪ´øÓÐ PVDF µÄ»ÆÍ(Ê®·ÖÖ®Ò»ºÍ ¶þ·ÖÖ®Ò»Ó¢´ç¿Ú¾¶µÄ¿ÉÌṩ 316²»Ðâ¸ÖÖ÷Ìå)¡£Î¬Í¨Ïð½ºÃÜ·â¼þΪ±ê×¼ÅäÖã¬KalrezÃÜ·â¼þΪ¿ÉÑ¡¼þ¡£Óû§¿ÉÅäÖÃÑ¡Ïî:
¿ÉÒÔÔڲ˵¥ÖÐÑ¡ÔñµÄÌØÐÔ°üÀ¨:
¹¤³Ìµ¥Î»
(GPM, LPM, »ªÊÏ»òÉãÊÏ)
¿ÉÑ¡µÄ±¨¾¯×´Ì¬
ÔÚÉ趨µãÒÔϹرÕ
ÔÚÉ趨µãÒÔÏ´ò¿ª
É趨µã»òÂö³åÊä³ö
ÒºÌåÁ÷Ïò
³ýÁËÓÃÓÚ 12 ¼ÓÂØ»ò¸üСÁ÷Á¿µÄ CP ×°ÖÃÒÔÍ⣬¿Éת¶¯
µÄ¿ØÖÆÏä¶ÔÓÚËùÓÐ×°Öö¼ÊDZê×¼ÅäÖÃ
ÒDZí¹æ¸ñ:
Á÷Á¿
3 λÊý¿ÉÊÓ¶Á³ö×°ÖÃ, 0.3 Ó¢´ç¸ß¶È 3 Êý×ÖLED
ÏìӦʱ¼ä: Á÷Á¿¸Ä±ä 63% Ϊ1.5 Ãë
±¨¾¯ 5% FS ¾²´ø
¾«È·¶È ±2% FS
Öظ´¾«¶È ±.25%
ѹ½µ±È 10:1
ζÈ
ÏìӦʱ¼ä: ζȸıä 63% Ϊ1.8 Ãë
±¨¾¯ ±2% ¾²´ø
¾«È·¶È ±1% FS
Öظ´¾«¶È ± .25%
¶Á³ö×°Öà 4 mA @32°F, 20mA @210°F
Һѹ
300 PSIG (20 Bar) ¹¤×÷ѹÁ¦ (2" ºÍ¸üµÍ)
200 PSIG (13 Bar) ¹¤×÷ѹÁ¦ (3" ºÍ 4")
Ò»°ã¹æ¸ñ
ÒºÌåζÈÏÞÖÆ 35-210°F (2-99°C)
Íâ¿Ç¶î¶¨µÈ¼¶ IP 65, ÀàÐÍ 1, 3, 4, 12 ºÍ 13
¹ÜµÀÁ¬½Ó
NPT, BSPP ºÍ BSPT ´Æ½ÓÍ·£¬
3" ºÍ 4" ANSI 150# R.F. ·¨À¼COOLPOINT VORTEX FLOW METER FOR WATER vortex shedding flowmeters are designed for coolant or water flow from to 4 inch pipe sizes. Optionally, to 4 inch sizes have temperature transmitters. In -2 inch sizes, 316 Stainless Steel bodies and Kalrez seals make it suitable for low viscosity corrosive fluids. They cost a lot less than mag meters and they are OK with high particulate. Simple, reliable and inexpensive.
-