- 信德迈公司Murphy摩菲 CAN总线显示器PV101-C-M02
详细信息
品牌:MURPHY 型号:PV101-C-M02 加工定制:否 适用范围:发动机配套仪表 是否跨境货源:否 Murphy PV101-C-M02显示器
PV101-C Display GaugesPV101-C Display产品特性
- 兼容欧四排放标准
- 适用于采购J1939协议的电控发动机和其他设备
- 可显示50多个来自发动机和传动系统ECU的J1939标准参数
- 以文本方式显示动态故障和历史故障,设备故障一目了然
- 安装及接线简单方便,无需编程即可使用
PV101-C较比前一代产品,提供了更多的功能并增强了产品的耐用性。其中包括:
- Tier 4 Emissions Implementation (PV101-C only)
– Three icons indicating Active Regeneration, Inhibit Regeneration, and Diesel
Particulate Filter DPF) Restricted. Menu offers Auto DPF Regen and Request DPF Regen.
- OEM Menu - A password protected menu offers access to MODBUS Setup, Engine Speed Control ON/OFF, and other critical menu
items that require restricted access.
- TSC1 (Torque Speed Control) (PV101-C only) – Allows user to set run speed via CAN if supported by engine manufacturer.
- Additional 4-Up Screen (PV101-C only) – Allows user to have two 4-Up screens to toggle between. Second user configurable screen is defaulted to show Tier 4 Parameters; DEF Level (Diesel Exhaust Fluid Level), DPF Active Regen Status, Exhaust Filter Outlet Temp, and Exhaust Filter Inlet Temp.
- Multiple language options Russian, Czech, Brazilian Portuguese, Chinese, and Japanese models have been added to the line of
existing languages (English, Spanish, French, German, and Italian).
- Sender Input Select between backlight dimmer function or fuel level. Can be calibrated to use non-Murphy fuel senders.
- Service Reminders – 5 service reminders allow users to set hours for: Change Engine Oil, Change Air Filters, Change Hydraulic Oil, Service Engine, and Service Machine.
- Select Source Address – Select the exact address the PV101 will claim on the Bus.
- Select CANbus Data Rate – Allows user to select CANBUS data rate.
- PV101-C Configuration Tool (PV101-C only) – PC tool allows users to create, view, edit and download configurations for the PV101.
- The PV101-C Display Gauges – Compatible with PVA and PVM gages, as well as additional J1939 I/O modules.
Other components in the MurphyLink system include micro-processor-based PowerView Analog (PVA) Gages for displaying critical
engine data broadcast by an electronic engine or transmission’s Engine Control Unit (ECU); engine RPM, oil pressure, coolant temperature, and system voltage. A combination audible alarm/relay unit offers warning and shutdown alerts. Up to 32 components may be linked to the PowerView using a simple daisy chain wire connection scheme using RS485. The PowerView and all connected components can be powered by either 12 or 24-volt systems.PV101-C Display参数显示
下列为PV101以英制或公制单位显示的部分发动机和传动系统参数。(使用时,请向发动机或传动系统制造商咨询其所支持的SAEJ1939参数)
- Engine RPM
- Engine Hours
- Fuel Rate
- System Voltage
- % Engine Load at the Current RPM
- Coolant Temperature
- Catalyst Level
- Oil Pressure
- Fuel Economy
- Throttle Position
- Engine Manifold Air Temperature
- Current Fuel Consumption
- Transmission Oil Pressure
- NMEA 2000 GPS Parameters
- Transmission Oil Temperature
- Transmission Gear Position
- Active Service codes
- Stored Service Codes (when supported)
- View Engine Configuration
ParametersPV101-C (78700439) : PowerView Display Module
The new PowerView Model PV101-C is Murphy's latest display in the J1939 MurphyLink family of components. Much like the PV101-A, this display providesPart NumberModel NumberDescriptionLanguages Available
78700439 PV101-C
Murphy STD English, Spanish, French, Italian, German
78700497 PV101-C-M01
Murphy STD Russian English, Russian, French, German, Spanish
78700498 PV101-C-M02
Murphy STD Chinese English, Chinese
78700499 PV101-C-M03
Murphy STD Japanese English, Japanese
78700500 PV101-C-M04
Murphy STD Brazilian Portuguese English, Brazilian Portuguese, French, German, Spanish
78700501 PV101-C-M05
Murphy STD Czech English, Czech, French, German, Spanish
78700435 PV101-C Configuration
Tool Kit User Configuration ToolPowerView. - Model PV101
Features
- Tier 4I/Euro Stage IV (PV101-C)
- Tier 3/Euro Stage III and earlier (PV101-A)
- For modern electronic engines and equipment applica-tions using SAE J1939 Controller Area Network
- Displays active and ECU-stored faults with text description for diagnosing equipment malfunctions
- Displays over 50 standard SAE J1939 parameters
- Tier 4 emissions compliant
- Software configurable with configuration toolThe PowerView PV101 display is a multifunction tool that enables equipment operators to view standard engine and transmission parameters as well as active and stored trouble codes. The display can show a single parameter or a four-parameter simultaneous dis-play. Diagnostic capabilities include codes with text description for most common fault conditions. The enhanced alarm indicators have ultra-bright alarm and shutdown LEDs (amber and red). The PV101-C and PV101-A have many features including:
-
Tier 4 Emissions Implementation (PV101-C only) – Three icons indicating Active Regeneration, Inhibit Regeneration, and Diesel Particulate Filter DPF) Restricted. Menu offers Auto DPF Regen and Request DPF Regen.-
OEM Menu - A password protected menu offers access to MODBUS Setup, Engine Speed Control ON/OFF, and other critical menu items that require restricted access.-
TSC1 (Torque Speed Control) (PV101-C only) – Allows user to set run speed via CAN if supported by engine manufacturer.-
Additional 4-Up Screen (PV101-C only) – Allows user to have two 4-Up screens to toggle between. Second user configurable screen is defaulted to show Tier 4 Parameters; DEF Level (Diesel Exhaust Fluid Level), DPF Active Regen Status, Exhaust Filter Outlet Temp, and Exhaust Filter Inlet Temp.-
Multiple language options . Russian, Czech, Brazilian Portuguese, Chinese, and Japanese models have been added to the line of existing languages (English, Spanish, French, German, and Italian).-
Sender Input . Select between backlight dimmer function or fuel level. Can be calibrated to use non-Murphy fuel senders.-
Service Reminders – 5 service reminders allow users to set hours for: Change Engine Oil, Change Air Filters, Change Hydraulic Oil, Service Engine, and Service Machine.-
Select Source Address – Select the exact address the PV101 will claim on the Bus.-
Select CANbus Data Rate – Allows user to select CANBUS data rate.-
PV101-C Configuration Tool (PV101-C only) – PC tool allows users to create, view, edit and download configurations for the PV101..
The PV101-C Display Gauges – Compatible with PVA and PVM gages, as well as additional J1939 I/O modules.Other components in the MurphyLink system include micro-processor-based PowerView Analog (PVA) Gages for displaying critical engine data broadcast by an electronic engine or transmission’s Engine Control Unit (ECU); engine RPM, oil pressure, coolant tempera-ture, and system voltage. A combination audible alarm/relay unit offers warning and shutdown alerts. Up to 32 components may be linked to the PowerView using a simple daisy chain wire connection scheme using RS485. The PowerView and all connected components can be powered by either 12 or 24-volt systems.
Display Parameters
The following are some of the engine and transmission parameters displayed by the PowerView (when applicable, consult engine or transmission manufacturer for SAE J1939 supported parameters). The PowerView can display these parameters in all available lan-
guages, as well as in English or Metric units.
. Engine RPM . Oil Pressure . Transmission Oil Temperature
. Engine Hours . Fuel Economy . Transmission Gear Position
. Fuel Rate . Throttle Position . Active Service codes
. System Voltage . % Engine Load at the Current RPM . Coolant Temperature . Catalyst Level . Engine Manifold Air Temperature . Current Fuel Consumption . Transmission Oil Pressure . NMEA 2000 GPS Parameters . Stored Service Codes (when supported) . View Engine Configuration ParametersSpecifications
Operating Voltage
.8 - 32 VDC
Reversed Polarity: Withstands reversed battery terminal polarity indef-initely within operating temperatures.
Environmental
Operating Temperature: -40o to +85oC (-40o to +185oF)
Display Viewing Temperature: -29o to +85oC (-20o to +185oF)
Storage Temperature: -40o to +85oC (-40o to +185oF) Environmental Sealing: IP68, ± 5 PSI (± 34kPa) Power Supply Operating Current
- (@ 14VDC) 52 mA min.: 300 mA max. (@ 32VDC) 1A max (with LCD heater) CAN Bus: SAE J1939 compliant
Product Dimensions
Case: Polycarbonate/polyester Maximum Panel Thickness: 3/8 inch (9.6 mm) Auxiliary RS485 Communications Port
- User configurable as Modbus MASTER or Modbus RTU SLAVE- MASTER ACTIVE (default) drives optional PVA or PVM gages
. SLAVE ACTIVE offers user adjustable communication parameters Resistive Input: (user selectable as one of the following)
- Backlighting Poteniometer: 1 K Ohm, 1/4 W
- Murphy Fuel Sender: 33 Ohm full, 240 Ohm empty set standard from factory for use with Murphy fuel sender. Programmable for use withnon-Murphy fuel senders.
Shipping Weights (all models): 1 Lb. (450 g.)
Shipping Dimensions (all models): 5 x 6 x 6 in. (127 x 152 x 152 mm) Clamp: PBT Connectors: 6-pin Deutsch DT Series
How to Order
Part Number Model Description Languages Available
78700439 PV101-C Murphy STD English, Spanish, French, Italian, German
78700497 PV101-C-M01 ,Murphy STD Russian English, Russian, French, German, Spanish
78700498 PV101-C-M02 , Murphy STD Chinese English, Chinese
78700499 PV101-C-M03 , Murphy STD Japanese English, Japanese
78700500 PV101-C-M04 ,Murphy STD Brazilian Portuguese English, Brazilian Portuguese, French, German, Spanish
78700501 PV101-C-M05 , Murphy STD Czech English, Czech, French, German, Spanish
78700435 PV101-C Configuration Tool Kit User Configuration Tool
78700244 PV101-A Murphy STD English, Spanish, French, Italian, German
78700396 PV101-A-M01 , Murphy STD Russian English, Russian, French, German, Spanish
78700409 PV101-A-M02 ,Murphy STD Chinese* English, Chinese
78700411 PV101-A-M03 ,Murphy STD Japanese* English, Japanese
*Added features not available in these language models